Abstract
Modern surgery usage of metal implants demands the new requirements for their quality and special properties. In particular, when treating damaged bones, problems of implant integration into tissues often arise (due to allergic reactions, inflammatory processes etc.). This issue is especially actual due to the war in Ukraine, which cause a huge number of wounds and injuries. The most promising way to overcome this problem is to create biocompatible and stable coatings on the surface of metal implants. The reported investigations deal with the preparation of biocompatible coatings on the surface of model metal implants which is based on a combination of hydroxyapatite and zirconium dioxide (doped with 5% wt. yttrium oxide) using the gas detonation deposition (GDD) method. The initial complex-substituted hydroxyapatites containing sodium ions and carbonate groups were obtained by precipitation from aqueous solutions (systems Na+ - Ca2+ - CO32- - NO3- - PO43-), and their fine dispersed mixture with ZrO2 to create coatings was carried out mechanically. The investigations of a structure and a composition of the coatings was carried out using powder X-ray diffracion, differential thermal analysis, scanning electron microscopy and IR spectroscopy. Preliminary medical and biological tests on animals (rats) revealed that the obtained results can be used in the creation of new generation medical implants for surgery, orthopedics and dentistry. Partial resorption of hydroxyapatite on the surface of the implants was revealed, which contributes to the formation of the interface between the implant and the bone and the formation of the primary cellular matrix. Among the main advantages of using the GDD method for deposition of controlled structure and composition coatings on metal substrate it should be noted both the relatively low cost and the possibility of creating a coating with high adhesion. This indicates significant prospects for the outlined approach for practical application in the therapy of damaged bones.
References
Duan Y., Ma W., Li D., Wang T., Liu B. Enhanced osseointegration of titanium implants in a rat model of osteoporosis using multilayer bone mesenchymal stem cell sheets, Exp. Ther. Med. 2017. 14: 5717–5726.
https://doi.org/10.3892/etm.2017.5303
Jing D., Tong S., Zhai M., Li X., Cai J., Wu Y., Shen G., Zhang X., Xu Q., Guo Z., Luo E. Effect of low-level mechanical vibration on osteogenesis and osseointegration of porous titanium implants in the repair of long bone defects. Sci. Rep. 2015. 5: 17134.
https://doi.org/10.1038/srep17134.
Miki T., Matsuno T., Hashimoto Y., Miyake A., Satomi T., Vitro and in vivo evaluation of titanium surface modification for biological aging by electrolytic reducing ionic water. Appl. Sci. 2019. 9: 713.
https://doi.org/10.3390/app9040713
Nayak S., Dey T., Naskar D., Kundu S.C. The promotion of osseointegration of titanium surfaces by coating with silk protein sericin. Biomaterials. 2013. 34: 2855–2864.
https://doi.org/10.1016/j.biomaterials.2013.01. 019
Moore B., Asadi E., Lewis G. Deposition methods for microstructured and nanostructured coatings on metallic bone implants: a review, Adv. Mater. Sci. Eng. 2017. 1–9.
https://doi.org/10.1155/2017/5812907.
Łatka L., Pawłowski L., Winnicki M., Sokołowski P., Małachowska A., Kozerski S. Review of functionally graded thermal sprayed coatings, Appl. Sci. 2020. 10: 5153.
https://doi.org/10.3390/app10155153
Gan J.A., Berndt C.C. Nanocomposite coatings: thermal spray processing, microstructure and performance, Int. Mater. Rev. 2015. 60: 195–244.
https://doi.org/10.1179/1743280414y.0000000048.
Strutynska N., Zatovsky I., Slobodyanik N., Malyshenko A., Prylutskyy Yu., Prymak O., Vorona I., Ishchenko S., Baran N., Byeda A., Mischanchuk A. Preparation, characterization, and thermal transformation of poorly crystalline sodium- and carbonate-substituted calcium phosphate. Eur. J. Inorg. Chem. 2015. 622–629.
https://doi.org/10.1002/ejic.201402761
Rapacz-Kmita A., Slosarczyk A., Paszkiewicz Z., Paluszkiewicz C. Phase stability of hydroxyapatite–zirconia (HAp–ZrO2) composites for bone replacement. J. Molec. Str. 2004. 704: 333–340.
https://doi.org/10.1016/j.molstruc.2004.02.047
Klyui N.I., Temchenko V.P., Gryshkov A.P., Dubok V.A., Shynkaruk A.V., Lyashenko B.A., Barynov S.M. Properties of the hydroxyapatite coatings, obtained by gas-detonation deposition onto titanium substrates. Funct. Mater.2011. 18: 285–292.
http://www.functmaterials.org.ua/contents/ 18-3/fm183-01.pdf
Malyshenko A.I., StrutynskaN.Yu., Zatovsky I.V., Slobodyanik N.S., Epple M., Prymak O. Synthesis of Na+,CO32--containing calcium phosphate nanoparticles and their thermal transformations. Funct. Mater. 2014. 21(3): 333–337.
http://functmaterials.org.ua/contents/21-3/fm 213-16.pdf
Gryshkov O., Klyui N.I., Temchenko V.P., Kyselov V.S., Chatterjee A., Belyaev A.E., Lauterboeck L., Iarmolenko D., Glasmacher B. Porous biomorphic silicon carbide ceramics coated with hydroxyapatite as prospective materials for bone implants. Mater. Sc. Eng. C. 2016. 68: 143–152.
https://doi.org/10.1016/j.msec.2016.05.113
Klyui N.I., Chornyi V.S., Zatovsky I.V., Tsabiy L.I., Buryanov A.A., Protsenko V.V., Temchenko V.P., Skryshevsky V.A., Glasmacher B., Gryshkov O. Properties of gas detonation ceramic coatings and their effect on the osseointegration of titanium implants for bone defect replacement. Ceram. Int. 2021. 47 (18): 25425–25439. https://doi.org/10.1016/j.ceramint.2021.05.265

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright (c) 2024 Іgor Zatovsky, Nataliia Strutynska, Ilariia Nikolenko, Volodymyr Temchenko, Ivan Ogorodnyk, Oleksii Lehenchuk, Ievgen Odynets, Mykola Slobodyanik