Abstract
This work demonstrates the possibility of using the anodic stripping voltammetry method on electrodes based on nanocrystalline thin films of yttrium-modified titanium dioxide to determine the content of lead (II) and, at the same time, oxygen in their joint presence in liquids, which is an urgent task in the development of multisensors toxic substances and oxygen in liquid media. Lead was determined by anodic potential scanning after preliminary electroconcentration of the electrode in the electrolyte solution containing Pb(II) ions; oxygen was determined by cathodic potential scanning. The influence of electroaccumulation conditions (potential and time), background electrolyte composition, and ions present on the analytical signal (AS) of lead (II) was studied. The analytical signal of lead exhibited a linear dependence on the concentration of Pb(II) ions in the electrolyte, spanning a concentration range of 0.01 to 8 mg·l-1. The maximum sensitivity of the electrodes to dissolved oxygen was (3÷6)·10-3 mg·l-1, to Pb(II) – 0.01 mg·l-1.
References
Kumar A, Kumar A, Cabral-Pinto M.M.S., Chaturvedi A.K., Shabnam A.A., et al. Lead Toxicity: Health Hazards, Influence on Food Chain, and Sustainable Remediation Approaches. Int J Environment Res Public Health. 2020. 17(7): 2179. doi: 10.3390/ijerph17072179
Nakaz MOZ Ukrayini № 721 vid 02.05.2022 «Pro zatverdzhennya Gigiyenichnih normativiv yakosti vodi vodnih ob'yektiv dlya zadovolennya pitnih, gospodarsko-pobutovih ta inshih potreb naselennya». (In Ukrainian).
Brainina Kh.Z. Stozhko N. Yu., Belysheva,. G.M.,Inzhevatova, O. V., Kolyadina . L.I. , Determination of heavy in untreated dry wines by anodic stripping voltammetry with modified thick-film electrode. Anal. Chim. Acta. 2004. 14(2): 227–234.
Barbeira Paulo J.S., Stradiotto Nelson R. S. Simultaneous determination of trace amounts of zinc, lead and copper in rum by anodic stripping voltammetry. Talanta. 1997. 44(2): 185–188. doi:10.1016/s0039-9140(96)02030-9.
Baldo М.А., Bragato C., Daniele S. Determination of Lead and Copper in Wine by Anodic Stripping Voltammetry With Mercury Microelectrodes: Assessment of the Influence of Sample Pretreatment Procedures. The Analyst. 1997. 122(1): 1–5. doi:10.1039/a605370j.
Daniele S., Baldo M.-A., Ugo P., Mazzocchin, G.-A. Determination of heavy metals in real samples by anodic stripping voltammetry with mercury microelectrodes. Analytica Chimica Acta. 1989. 219: 19–26. doi:10.1016/s0003-2670(00)80329-3.
Metrohm. Determination of cadmium and lead by anodic stripping voltammetry at a mercury film electrode.–Application Bulletin 241/2e, 14p. https://www.metrohm.com/ru-ru/applications/AB-241.
Mikkelsen, Ø., Schrøder, K. H. Voltammetry using a dental amalgam electrode for heavy metal monitoring of wines and spirits. Analytica Chimica Acta. 2002. 458(1): 249–256. doi:10.1016/s0003-2670(01)01606-3.
Hwang J.-H., Wang X., Zhao D., Rex M. M., Cho H. J., Lee W. H. A novel nanoporous bismuth electrode sensor for in situ heavy metal detection. Electrochimica Acta. 2019. 298: 440–448. doi:10.1016/j.electacta.2018.12.122.
Li. X., Zhou H. Fu C., Wang F., Ding Y., Kuang Y. A novel design of engineered multi-walled carbon nanotubes material and its improved performance in simultaneous detection of Cd(II) and Pb(II) by square wave anodic stripping voltammetry. Sensors and Actuators B: Chemical. 2016. 236:144–152. doi:10.1016/j.snb.2016.05.149.
Lu Z., Zhang J., Dai W. et al. A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II). Microchim Acta. 2017. 184: 4731–4740. doi.org/10.1007/s00604-017-2521-8.
Song W., Zhang L., Shi L., Li D.-W., Li Y., Long, Y.-T. . Simultaneous determination of cadmium(II), lead(II) and copper(II) by using a screen-printed electrode modified with mercury nano-droplets. Microchimica Acta. 2010. 169(3-4): 321–326 doi:10.1007/s00604-010-0354-9.
Afkhami A., Ghaedi H., Madrakian T., Rezaeivala M. Highly sensitive simultaneous electrochemical determination of trace amounts of Pb(II) and Cd(II) using a carbon paste electrode modified with multi-walled carbon nanotubes and a newly synthesized Schiff base. Electrochimica Acta. 2013. 89: 377–386.
Lu Z., Yang S., Yang Q., Luo S., Liu C., Tang Y. A glassy carbon electrode modified with graphene, gold nanoparticles and chitosan for ultrasensitive determination of lead(II). Microchimica Acta. 2013. 180(7-8): 555–562. doi:10.1007/s00604-013-0959-x.
Baghayeri M., Alinezhad H., Fayazi M., Tarahomi M., Ghanei-Motlagh R., Maleki B. A novel electrochemical sensor based on a glassy carbon electrode modified with dendrimer functionalized magnetic graphene oxide for simultaneous determination of trace Pb(II) and Cd(II). Electrochimica Acta. 2019. 312: 8088. doi:10.1016/j.electacta.2019.04.180.
Seifi A., Afkhami A. & Madrakian T. Highly sensitive and simultaneous electrochemical determination of lead and cadmium ions by poly(thionine)/MWCNTs-modified glassy carbon electrode in the presence of bismuth ions. J. Appl. Electrochem. 2022. 52: 1513–1523. https://doi.org/10.1007/s10800-022-01728-4.
Никитина Н.А., Растворова Е.Г., Бойченко А.П. Инверсионное вольтамперометрическое определение меди (ІІ) и свинца (ІІ)с применением углеситаллового єлектрода. Вісник Харківського національного університету. – 2011;976. – Хімія. Вип. 20(43): 208-215.
Lu Z., Zhang J., Dai W. et al. A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II). Microchim Acta. 2017. 184: 4731–4740 https://doi.org/10.1007/s00604-017-2521-8/
.Sawan S., Maalouf R., Errachid A. Jaffrezic-Renault. Metal and Metal Oxide Nanoparticles in the Voltammetric Detection of Heavy Metals: A Review. TrAC Trends in Analytical Chemistry. 2020. 131: 116014.
Hai T., Hung L. C., Phuong T.T.B., Ha B.T.T., Nguyen B.S., Hai T.D., Nguyen V.H. Multiwall carbon nanotube modified by antimony oxide (Sb2O3/MWCNTs) paste electrode for the simultaneous electrochemical detection of cadmium and lead ions. Microchemical Journal. 2020. 153: 104456. doi:10.1016/j.microc.2019 104456.
Memon F., Ameen S., Qambrani N., Buledi J.A., Khand N. H. , Solangi, A. R., Taqvi S. I. H, Karaman C Karimi F., Afsharmanesh E. An improved electrochemical sensor based on triton X-100 functionalized SnO2 nanoparticles for ultrasensitive determination of cadmium. Chemosphere. 2022. 300: 134634.
Fernandez-Bobes С. Anodic stripping of heavy metals using a hanging mercury drop electrode in a flow system/ С. Fernandez-Bobes, M.T. Fernandez-Abedul et. al. Electroanalysis. 1998. 10(10): 701–706.
Stozhko N.Y., Lipunova G.N., Maslakova T.I. et al. A Thick-Film Carbon-Containing Electrode Modified with Formazan for Determining Copper, Lead, Cadmium, and Zinc. Journal of Analytical Chemistry. 2004. 59: 179–184. https://doi.org/10.1023/B:JANC.0000014748.34212.79
Rievaj M., Tomčik Р., М., Čerňanska М. et. al Trace determination of lead in environmental and biological samples by anodic stripping voltammetry on carbon paste electrode. Chem. anal. 2008. 53(5): 717–723.
Armstrong K.C., Tatum С.Е., Dansby-Sparks R.N et. al. Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode. Talanta. 2010. 82(2): 675–680.
Zavarise F.D., Merli D., Profumo А. Determination of Pb(2+) in natural waters with 2- mercaptobenzimidazole-5-sulfonate (MBIS)chemically modified gold electrode. Anal. chim. acta. 2010. 668(2): 17–181.
Mhammedi M.A., Achak М., Bakassе М. et. al Electroanalytical method for determination of lead(II) in orange and apple using kaolin modified platinum electrode. Chemosphere. 2009. 76(8): 1130–1134.
Bas B., М. Jakubowska М. The renovated silver ring electrode in determination of lead traces by differential pulse anodic stripping voltammetry. Anal. chim. Acta. 2008. 615(1): 39–46.
Qijin W., Fen Y., Lina Z. et. al. Bucky-gel coated glassy carbon electrodes, for voltammetric detection of femtomolar leveled lead ions. Talanta. 2010. 82(5): 1820–1825.
Jing L. , Shaojun , G, Yueming Z., Erkang W. High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite film L. Jing, G. Anal. chim. acta. 2009. 649(2): 196–201.
Vorobets V.S., Kolbasov G.Ya., .Medyk I.A, Harashchenko A.Yu., Karpenko S.V, Oblovatna S.Ya, .Antoniuk, N.G Synthesis, Photo- and Electrocatalytic Properties of Nanostructured Y-TiO2 Films. Surface Engineering and Applied Electrochemistry. 2021. 57(5): 535–541. doi.org/10.3103/S1068375521050136.
Kolbasov G.Ya. Elektrody dlia sensora rozchynenoho kysniu na osnovi oksydiv Ti, Zr ta W. G.Ya.Kolbasov, V.S. Vorobets. "Doslidzhennia u haluzi sensornykh system ta tekhnolohii": zbirnyk naukovykh prats z kompleksnoi prohramy fundamentalnykh doslidzhen NAN Ukrainy. Kyiv. 2006. 267–276.
